979User Manual 1173.9411.02 ─ 19
CALCulate:LIMit<k>:CONTrol:MODE <Mode>
This command selects the horizontal limit line scaling.
Parameters:
<Mode> ABSolute
Limit line is defined by absolute physical values (Hz or s).
RELative
Limit line is defined by relative values related to the center fre-
quency (frequency domain) or the left diagram border (time
domain).
*RST: ABSolute
CALCulate:LIMit<k>:CONTrol:OFFSet <Offset>
This command defines an offset for a complete limit line.
Compared to shifting the limit line, an offset does not actually change the limit line defi-
nition points.
Parameters:
<Offset> Numeric value.
The unit depends on the scale of the x-axis.
*RST: 0
Manual operation: See "X-Offset" on page 530
CALCulate:LIMit<k>:CONTrol:SHIFt <Distance>
This command moves a complete limit line horizontally.
Compared to defining an offset, this command actually changes the limit line definition
points by the value you define.
Parameters:
<Distance> Numeric value.
The unit depends on the scale of the x-axis.
Manual operation: See "Shift x" on page 534
CALCulate:LIMit<k>:CONTrol:SPACing <InterpolMode>
This command selects linear or logarithmic interpolation for the calculation of limit lines
from one horizontal point to the next.
Parameters:
<InterpolMode> LINear | LOGarithmic
*RST: LIN
Example:
CALC:LIM:CONT:SPAC LIN