Remote-Control Commands
R&S
®
SMW-K144
218User Manual 1178.8013.02 ─ 06
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:POWer <Power>
Sets the power for the selected allocation relative to the power of the other allocations.
Parameters:
<Power> float
Range: -80 to 10.0
Increment: 0.01
*RST: 0.0
Example: See Example "Configuring the configurable allocations in the
users and BWPs groups" on page 152.
Manual operation: See "Power" on page 86
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:STATe <State>
Activates the allocation.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Configuring the configurable allocations in the
users and BWPs groups" on page 152.
Manual operation: See "State" on page 86
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:REPetitions <Repetition>
Defines if and how often the allocation is repeated.
Parameters:
<Repetition> OFF | SUBFrame | FRAMe | SLOT
*RST: depends on allocation number
Example: See Example "Configuring the configurable allocations in the
users and BWPs groups" on page 152.
Manual operation: See "Repetition" on page 86