A Message Appears
7
FAQ
181
[INSTALL DRAIN BOTTLE]
Check whether the drain bottle is installed. Install the drain bottle, then press .
[CHECK DRAIN BOTTLE]
This appears when a certain amount of discharged uid collects in the drain bottle. To clear the message,
press
. If this screen appears, go to the [DRAIN BOTTLE] menu and discard the discharged uid in
the bottle.
P. 95, "Disposing of Discharged Ink"
[SET HEAD HEIGHT TO xxx]
The height of the print heads is lower than the height specied on the computer. The heads move to a location
where you can operate the height-adjustment lever. Adjust to the displayed height, then press
.
[REMOVE MEDIA CLAMPS]
This appears when media cuto is attempted without rst removing the media clamps. The media cuto
starts when
is pressed after the media clamps are removed. Pressing while this message
is displayed quits cuto.
[TIME FOR MAINTENANCE]
The time has come to perform the manual cleaning. After verifying, press .
P. 102, “Performing Manual Cleaning”
[TIME FOR WIPER REPLACE]
It is time to replace the wipers. After verifying, press .
P. 111, "Replacing the Wiper"