79
Other Functions
Making the Sequencer Run Automatically (Auto Sequence)
Use the auto sequence feature when you want to make the functions recorded in the sequencer execute automatically.
Conguring the auto sequence settings
Set the action or function that’s executed when the sequencer advances
to the next function. You can add some delay time before the next
function is executed, or pause the execution of a function.
1. In step 1 of “Recording to the Sequencer” (p. 76), bring up
the operation list.
2. Touch the line to edit.
A popup menu appears.
3. Touch <EDIT FUNCTION>.
The edit screen for the operation to record to the sequencer appears.
4. Touch <TIME> to select the action for moving to the next
operation.
Value Explanation
Pause Pauses the auto sequence.
AUTO Executes the next operation in the sequence.
1–120sec
Executes the next operation after delaying for a
specied amount of time.
5. Repeat steps 2–4.
6. Press the [EXIT] button to close the screen.
Running the auto sequence
1. Use the operations in steps 1–3 of “Running the Sequencer”
(p. 78) to turn the sequencer ON”.
The list of operations recorded in the sequencer is shown.
2. Touch <AUTO> to turn the auto sequencer function on.
The functions in the list are executed, starting at the beginning.
When the last function is nished, the sequence stops automatically.
When a function is set to “PAUSE”
When the function is nished, auto sequence is paused. You can press
the [AUTO] (NEXT) button to manually execute the next function.
* When executing a function that’s set to a value other than “PAUSE”, the
auto sequence is resumed.
3. Touch <AUTO> again to turn o the auto sequence.
4. To turn the sequencer function o, using the operations
in steps 1–3 of “Running the Sequencer” (p. 78) and set
SEQUENCER to “OFF”.
MEMO
You can repeatedly execute functions that are in a list. When the last
function is nished, the sequencer returns to the beginning.
From the [MENU] button
Ó
“MEMORY/MACRO/SEQ”
Ó
“SEQUENCER”
Ó
set “REPEAT EXECUTE” to “ON”.