SatLab SLT12 - Cautions

SatLab SLT12
215 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SLT12 User Manual
3
The instrument has the image-assisted stakeout function, which can display the stakeout point mark on the
software interface, which is convenient for aiming at the stakeout point.
1.2 Cautions
1. Avoid looking directly into the sun with the eyepiece when measuring. Recommended to use a solar filter to
reduce the impact.
2. Avoid extreme temperatures when storing equipment and sudden changes in temperature when using the
instrument.
3. The instrument should be loaded in the box placed in a dry and ventilated place and prevented from shock,
dust, and moisture when it is not in use.
4. To get good accuracy, you should leave the instrument in the box if the instrument temperature has a large
difference between working and storing you may unpack the box and employ the instrument until the instrument
reaches the temperature at the working field.
5. If the instrument is not used for a long time, the battery should be unloaded and stored separately and charged
once a month to prolong battery life.
6. The instrument should be installed in the box when it is transported. Extrusion, collision, and violent vibration
need to be carefully avoided during the transport process. The soft mat May be placed around the box on
long-distance transportation.
7. It is better to use a high-quality wooden footstool to make sure the stability of measurement and improve its
accuracy when setting up the instrument.
8. Only use absorbent cotton or lens paper to wipe the instrument gently if the exposed optical device needs to be
cleaned.
9. Use a flannelette or a hairbrush to clean the instrument after use. Do not electrify and start up after the device
got wet in the rain. Using a clean soft cloth to wipe it dry and put it in a ventilated place for some time to make
the instrument fully dry before using or packing.
10. Inspect the instrument carefully and comprehensively to ensure its indicators, function, power supply, the
initial setting, and correction parameters meet the requirements before operating.
11. If the function is abnormal, non-professional maintenance persons are not allowed to dismantle the device
without authorization in case of any unnecessary damage.
12. The emitted light of the no-prism total station is a laser, do not direct to the eyes.