SLT12 User Manual
24
Users can choose whether to turn on the tilt compensation or not according to the actual operation scenario. To
ensure the accuracy of the angle measurement, it is recommended not to turn off the tilt compensation, whose
display can also be used to better level the instrument. If the "compensation over the limit" appears, it indicates
that the instrument is out of the range of automatic compensation, and the foot screw must be adjusted for
leveling.
b. Set up the Target Type
Our series total station has three reflectors that can be selected, prism, non-prism (NP), and sheet(reflect sheet),
users can set them according to their operational needs.
Figure 4- 2
c. Set up the Atmospheric Correction
When measuring distance, the measured value will be affected by the atmosphere. To reduce this, atmospheric
correction parameters are needed.
Click the upper left button to open the [Menu] bar and click [PPM] to set it.