Section 5: Two-Dimensional Symbols
SATO Programming Reference Page 5-7
Label Set #2
Special Notes 1. The maximum number of <ESC>FX Sequential Numbering commands
that can be used in one job is eight.
2. In the example above four total labels will be printed
(<ESC>FX002+005003<ESC>DC00006000), the sequential number-
ing will start at position 5 and the three digits “600” will be incremented
in steps of 1. A total of two sets of labels will be printed, the first set of
two labels with the value “00006000” and the next two label set with the
value “00006010”. Label Set #1 Label Set #2 1st Label 00006000 3rd
Label 00006010 2nd Label 00006000 4th Label 00006010
3. The <ESC>Q Label Quantity command must be set for the total number
of labels to be printed. In the above example, the value for the <ESC>Q
command should be 2 sets x 2 labels/set = 4. If, in the above example, it
was set to a value of “1”, only the first label would be printed.