Section 6: Configuration Commands
Page 6-6 SATO Programming Reference
Placement: Separate data stream sent to printer
Default: None
COMMAND FUNCTION To set the printer default configuration into EEPROM
INPUT TO PRINTER <ESC>A
<ESC>PC26,0
<ESC>Z
PRINTER OUTPUT There is no printer output as a result of this command. This command
example enables the buzzer.
SPECIAL NOTES 1. All command setting values must be in ASCII format.
2. These settings are stored in EEPROM and will remain valid until
receipt of another <ESC>PC command.
3. All positions in this command must be separated by a comma. If the
parameter. To change multiple settings, the correct number of com-
mas must be placed in the command, i.e. to change the label gap
sensor to reflective (eye-mark), the command would be:
<ESC>PC, , , , , , , , ,0, , , , , , , , , , , , , , , , , .
4. If only one setting is to be changed, the “aa” parameter must be an
“F”.