COUNTER STATUS (SOH + ME)
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ASCII ME
causes the printer to return a 28 byte Head Counter Status Word bounded by an STX-
ETX pair that reports the current status of the printer life counters.
15 00
01
Fixed Pitch
Proportional Pitch
16-17 00 to C80
00 to 12C
Not Supported
18-19 00 to 340
00 to 4E0
Not Supported
20-21 00 to 3E7
FFFF to
FC19
Vertical Base Reference Point Offset in dots (0 to 792)
Vertical Base Reference Point Offset in dots (-1 to -792)
22-23 00 to 320
00 to FCE0
Horizontal Base Reference Point Offset in dots (0 to 800)
Horizontal Base Reference Point Offset in dots (-1 to -800)
24 00 tp 63
FF to 9D
Not Supported
25 00 tp 63
FF to 9D
Not Supported
26 00 tp 63
FF to 9D
Not Supported
27 00 tp 63
FF to 9D
Dispense Offset in dots (0 to 99)
Dispense Offset in dots (-1 to -99)
28 00
01
Compatibility Mode Enabled
Compatibility Mode Disabled
29 08 to 40 Not Supported
30 00
01
Buzzer Enabled
Buzzer Disabled
BYTE
NUMBER
HEX VALUE DESCRIPTION
1 - 8 Hex Current Life Counter in dots
9 - 12 Hex 1st (Current) Head Counter in dots
13 - 16 Hex 2nd (Previous) Head Counter in dots
17 - 20 Hex 3rd Head Counter in dots
21 - 24 Hex Not Supported
BYTE
NUMBER
HEX VALUE DESCRIPTION