4 Operation and Configuration
181
S84-ex/S86-ex Operator Manual
RFID ERR OUTPUT
Set the output pattern at RFID error.
• PULSE: Single shot pulse output.
• LEVEL: Flat level output.
LENGTH OF PULSE
Set the pulse width.
The setting values are 100, 200, 300, 400 and 500 msec.
Note
Shows only if PULSE is selected in the RFID ERR OUTPUT screen.
READER VERSION
This screen shows the firmware version of the RFID module.
This screen is not shown correctly when the RFID module is neither
connected correctly nor configured correctly.
VIEW EPC DATA
Select whether or not to read and show the data of the RFID tag.
Tag needed to be set at the correct position (at antenna position) for
correct reading.
Press the
/ buttons to select the reading area from EPC, TID, USER
and PC.
• YES: The product reads and shows the data.
• NO: Do not read the data and proceed to the next screen.