4 Operation and Configuration
180
S84-ex/S86-ex Operator Manual
RFID LABEL DATA
Set the recovery operation at RFID tag error, and recovery conditions at
when the product paused due to MAX ERR COUNT (number of retries)
exceeding.
The options are as follows:
RELEASE: When an RFID tag error occurs, the product discards the
current writing data and failed label. The RFID error screen shows and
continues to print the next data. If the RFID error occurs continuously
and reaches the specified MAX ERR COUNT, printing pauses.
Press the
LINE button to discard the current writing data and
continues to the next print.
Press the FEED button to discard all data of the current item and
continues to the next item printing.
Press the
CANCEL button to discard all the item data including the
current data.
RETRY: When an RFID tag error occurs, the product attempts to write
the same data based on the specified MAX ERR COUNT. If the tag
error continues, an error message is shown and the product pauses.
Press the
LINE button to print again.
Press the FEED button to discard the data of the current item and
continues to the next item printing.
Press the
CANCEL button to discard all the item data including the
current data.
If the external signal is enabled and MAX ERR COUNT is set to 0, the
product does not display the error message, nor pause at tag error with
both RETRY/RELEASE, and continues printing with the external signal.
MAX ERR COUNT
Set the number of retries (release/reprint) at the RFID tag error.
The count starts after the RFID tag error occurs.
The product pauses with the error message when it has reached the
specified number of errors.
The setting range is from 0 to 9.
If you set to 0, the RFID error screen shows and printing continues.
RFID ERR SLASH
Select whether or not to print a slash on a tag when an RFID tag error
occurred.
YES: Prints a slash at the time of RFID tag error.
NO: Do not print a slash at the time of RFID tag error. Only RFID TAG
ERROR is printed.