8 Troubleshooting
303
S84-ex/S86-ex Operator Manual
13
Memory full error
Flashes red.
One long beep.
To clear the error:
Power off the
product.
The space in the memory
is not sufficient.
Delete unwanted data
from the memory.
14
Download data
error
Lights red.
One long beep.
The downloaded data is
incorrect.
Check the downloaded
data.
The download area is not
sufficient.
Check the downloaded
data size.
17
BCC check error
Flashes red.
Three short beeps.
To clear the error:
Press the LINE
button or cancel the
print job.
The BCC code of the data
to be sent (one item) is
incorrect.
Check the data to be sent
and the interface settings.
LINE button: Continue
printing from the print data
where the BCC error
occurred.
Send the SUB command:
Clear the BCC error and
continue printing from
where it stopped.
18
Item No. error
Flashes red.
Three short beeps.
To clear the error:
Press the LINE
button or cancel the
print job.
Sequence number of print
data (one item) is not
increased by one.
*The sequence number is
not in sequential order.
Check the data to be sent
and the interface settings.
LINE button: Continue
printing from the print data
where the Item No. error
occurred.
Send the SUB command:
Clear the Item No. error
and continue printing from
where it stopped.
Error
No.
Message LED/Buzzer Cause Countermeasure

Table of Contents