78
5) Steam boiler Selection menu for the steam boiler in use.
Option 1: "Not active" selection:
Switches the steam boiler off entirely.
All products that are prepared with
steam are deactivated.
Option 2: "Steam 2000" selection: W
Standard setting for SCA TouchIT.
Option 3: "Steam 3000" selection: W
Standard setting for SCA Plus Touch-
IT.
Option 4: "Steam 6000" selection: W
Special option. Only available with
mains connection 1 phase 30 A or 3
phases 16 A.
Not active
Steam 2000 W
Steam 3000 W
Steam 6000 W
The selection depends on
the machine equipment.
See the data under "Elec-
trical Ratings" on the serial
plate.
A 6000 W boiler contains
two heating elements.
6) Hotwater source "Not active" Selection menu for the hot water boiler in
use.
"Not active" selection:
Switches the hot water boiler off en-
tirely. All products that are prepared
with hot water are deactivated.
Not active
From coffee
boiler
Hot water
2000 W
Hot water
3000 W
Hot water
6000 W
See the setting in the "4
Mains connection" param-
eter.
6) Hotwater source "From coffee
boiler"
"From coffee boiler" selection:
Standard setting for SCA TouchIT.
Select "From coffee boiler".
"Hot water" appears for selection in
the "Product configuration".
Not active
From coffee
boiler
Hot water
2000 W
Hot water
3000 W
Hot water
6000 W
See the setting in the "4
Mains connection" param-
eter.
6) Hotwater source "2000 W" "Hot water 2000 W" selection:
Standard setting for SCA TouchIT.
Special option for SCA Plus TouchIT (machi-
ne with a coffee and hot water boiler, but
without a steam boiler).
Select "Hot water 2000 W".
Not active
From coffee
boiler
Hot water
2000 W
Hot water
3000 W
Hot water
6000 W
See the setting in the "4
Mains connection" param-
eter.
6) Hotwater source "3000 W" "Hot water 3000 W" selection:
Standard setting for SCA Plus TouchIT.
Select "Hot water 3000 W".
"Hot water" appears for selection in
the "Product configuration".
Not active
From coffee
boiler
Hot water
2000 W
Hot water
3000 W
Hot water
6000 W
See the setting in the "4
Mains connection" param-
eter.
Parameters: System parameters