www.schaerer.com System
PASCA_TOUCHIT_EN
V02 | 07.2013
96
19) M6 motor water pump Actuation of the water pump motor.
ON:
The water pump is switched on.
OFF:
The water pump is switched off.
On/off -
20) heater coffee water (*) Actuation of the coffee boiler heating.
ON:
The coffee boiler heating is switched
on.
OFF:
The coffee boiler heating is switched
off.
On/off (*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
21) heater hot water (*) Actuation of the hot water boiler heating.
ON:
The hot water boiler heating is
switched on.
OFF:
The hot water boiler heating is
switched off.
On/off (*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
22) heater steam (*) Actuation of the steam boiler heating.
ON:
The steam boiler heating is switched
on.
OFF:
The steam boiler heating is switched
off.
On/off (*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
23) Heating 6000 W (*) Actuation of the special boiler heating
6000 W. (second heating element)
ON:
The second boiler heating 6000 W is
switched on.
OFF:
The second boiler heating 6000 W is
switched off.
On/off (*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
Only with the appropriate
machine equipment and
activated system parame-
ter.
24) Ext. heating element 1 (*) "Central Cleaning" machine communication
between two machines regarding enabling of
cleaning.
ON:
Cleaning is enabled in the second
machine.
OFF:
No communication between the ma-
chines.
On/off Only if two machines are in
use.
Parameters: Output test
Display text Description Setting range Notes