EasyManua.ls Logo

SEW-Eurodrive MOVISAFE DCS21B

SEW-Eurodrive MOVISAFE DCS21B
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual – MOVIDRIVE® MDX61B Safety Module Option MOVISAFE® DCS..B
21
3
Safety functions
Integrated Safety Technology
3.2.5 SS2(c) – Safe Stop 2
When the SS2(c) function is active, the inverter brings the motor to a standstill electri-
cally. At standstill, the drive inverter delivers the power to keep the motor in position. The
position must be safely monitored after a specified, safety-relevant time has elapsed
(SOS function according to EN 61800-5-2).
This safety function corresponds to a controlled stop of the drive according to EN 60204-
1, stop category 2.
9007201429937291
Safety function monitors
Safety function trips
v=Velocity
t=Time
t
1
= Point of time when SS2(c) is activated and motor deceleration is triggered
t
2
= Point of time when SOS is triggered
t = Safety-related period of time
t
1
t
2
t
Δt
V
INFORMATION
The SS2(c) function does not monitor the stopping of the drive.
The safety-relevant period of time t allows the drive to come to a stop. In the event
of a fault, the drive does not come to a stop. It will not be de-energized until the time
t
2
(STO).
P
i
f
kVA
Hz
n

Table of Contents

Related product manuals