74
Manual – MOVIDRIVE® MDX61B Safety Module Option MOVISAFE® DCS..B
6
Parameter descriptions of parameter group P55x in MOVIDRIVE
®
B
Startup
6.2 Parameter descriptions of parameter group P55x in MOVIDRIVE
®
B
The parameter group P55x DCS safety module in MOVIDRIVE
®
B includes display and
setting values that are specific to the DCS..B option. The factory setting is underlined
.
6.2.1 P550 DCS safety module status
Display value that cannot be changed.
Parameter P550 shows the current status of the DCS..B option.
No DCS: No DCS..B option detected.
RUN: Normal operation.
STOP: Operation of option DCS..B was stopped via programming interface.
ALARM: The DCS..B option has issued an alarm.
ERROR: The DCS..B option has issued an error.
You have the following options to read the corresponding error or alarm message
from the error memory of the DCS..B option:
Via the XT service interface of MOVIDRIVE
®
B:
With the DBG60B keypad
With the MOVITOOLS
®
MotionStudio engineering software
Via the X87 service interface of the DCS..B option with the MOVISAFE
®
Assist/Con-
fig software interface.
6.2.2 P551 Digital inputs DCS DI1 – DI8
Display value that cannot be changed.
Parameter P551 shows the current status of the digital inputs of option DCS..B in the
order DI1 DI8.
6.2.3 P552 Digital outputs DCS DO0_P DO2_M
Display value that cannot be changed.
Parameter P552 shows the current status of the digital outputs of option DCS..B in the
following order:
DO0_P
DO0_M
DO1_P
DO1_M
DO2_P
DO2_M