72
Manual – MOVIDRIVE® MDX61B Safety Module Option MOVISAFE® DCS..B
6
General information on startup
Startup
6Startup
6.1 General information on startup
6.1.1 Requirements
• The following prerequisites must be fulfilled to ensure successful startup:
– The system must be configured correctly
– The MOVISAFE
®
Assist/Config software must be installed. The software is avail-
able on the MOVISAFE
®
software ROM, edition 04/2009, part number 1156 6604
– MOVITOOLS
®
MotionStudio version 4.50 or higher
– Firmware version of the MOVIDRIVE
®
MDX61B: 18220916.10 or higher
– Firmware version of MOVISAFE
®
DCS..B: 2.0.1.8 or higher
For detailed project planning information, refer to the online help of the MOVISAFE
®
Assist/Config software.
You find an explanation of the parameters in the online help of the MOVITOOLS
®
MotionStudio engineering software.
• Requirements for using the MOVISAFE
®
Assist/Config software:
– Only for MOVISAFE
®
Config: Activation with a USB license dongle (part number
1058 5834)
– Operating system: Microsoft Windows
®
2000, XP, Vista, 7 (MOVISAFE
®
Assist
only from version 1.9.1 and later)
– Required hard disk space: approx. 75 MB each
– RAM: Min. 256 MB, recommended 512 MB or more
– Required hardware component: Interface adapter USB11A (USB to RS485). For
more information on the USB11A interface adapter, refer to the MOVIDRIVE
®
MDX60B/61B catalog.
6.1.2 Startup steps for DCS21B/22B
• Make sure that
– the installation of the DCS21B/22B,
– the cabling,
– the terminal assignment, and
– the emergency switch-off
have been configured correctly and are suited to the application.
• Provide for suitable measures to prevent the motor from starting up unintentionally.
Take additional safety measures depending on the application to prevent possible in-
juries to people and damage to machinery.
• Switch on the line voltage and the DC 24 V supply voltage, if applicable.
• Start up the drive with MOVIDRIVE
®
MDX61B as described in the "MOVIDRIVE
®
MDX60B/61B" operating instructions.
• GSD file: GSD_DFS11B/12B (for PROFIBUS).
INFORMATION
• A detailed assessment is required for applications that are operated as group drive.
This can be checked by SEW-EURODRIVE in individual cases.
• Applications that consist of a drive train subject to slip must be assessed separately