EasyManua.ls Logo

SEW-Eurodrive MOVISAFE DCS21B

SEW-Eurodrive MOVISAFE DCS21B
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
78
Manual – MOVIDRIVE® MDX61B Safety Module Option MOVISAFE® DCS..B
6
Configuring the measuring sections
Startup
Measuring sections A and B must be configured accordingly for internal signal process-
ing. They are configured in the encoder screen of the MOVISAFE
®
Assist/Config
software interface (see below figure).
Note the following parameters when configuring the measuring section:
Parameters of the measuring section
You can choose "linear" or "rotary" for the measuring section.
Measuring section units
For a linear measuring section, you can choose "mm/s" or "m/s" as the unit for speed.
For a rotatory measuring section, you can choose "rev/s" or "rev/min" as the unit for
speed.
The selected resolution should correspond to the physics of the measuring section
to prevent rounding problems in the configuration.
Position processing
The position processing of the DCS..B option can be selected by enabling the
"Activate" checkbox. The measuring length determines the permitted position range
for position processing. It is important that the present position of the drive is within
the measuring length window. If this position range is left, the DCS..B option switches
off and issues alarm A3307. The measuring length has a range of 1 - 1 000 000 and
is normalized with the unit specified for the measuring section. "Encoder 2" is auto-
matically defined as absolute encoder. If position processing is disabled, only moni-
toring functions with velocity processing are permitted for parameter setting. This
means monitoring functions with position processing are disabled in the
MOVISAFE
®
Assist/Config software.
18014400483104651
00
I

Table of Contents