COMMISSIONING
If,insteadofadenedvolume,abulkwithadenedmassisavailable,youcanconvert
this into a volume if the bulk density is known and constant.
Mass [t]
Volume [m
3
] =
Bulk density [t/m
3
]
Compensation function
Two types of compensating functions are available.
Quadratic compensation function
A quadratic compensation function delivers
optimal results in the range where the refe-
rence measurements were made. However,
expected measurements outside of the
reference measurement range, could result
in a larger deviation.
Linear compensation function
A linear compensation function is re-
commended if measurements outside
of the reference measurement range are
expected.
Fig. 38: Compensation function
You can make use of the visualization to help you choose the best suited compensation
function for your application.