EasyManuals Logo

SICK FLOWSIC500 User Manual

SICK FLOWSIC500
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
166 FLOWSIC500 · Operating Instructions · 8025733/1GMJ/V4-2/2022-07 · © SICK Engineering GmbH
Annex
Subject to change without notice
Fig. 86 Control diagram 9215965 (page 7)
SICK Engineering GmbH
Bergener Ring 27
01458 Ottendorf-Okrilla
Verteildatum:
Page
Ersatz für:
Änderung
gez.
Tag
Name
Ind.
Tag Name
Maßstab:
Werkstoff
Ersetzt durch:
Gepr.
Ursprung:
MKO
7of7
2014-07-16
Connector. Function / signal internal Connection Operating
parameters
Safety
parameters*)
M8 (M12)
female
p or T s ensor
Pin 1 PWR (power supply out “+”) “p & T sensor”
4-pole connector,
coded
nominal
output voltage
3.3 V
Uo = 8.2 V
Io = 396 m A
Po = 716 mW
Co = 6.4 μF
Lo = 0.2 mH
Pin 2 DATA + (A)
Pin 3 GND (power supply out “–“)
Pin 4 DATA (B)
M8 (M12)
female
T or p s ensor
Pin 1 PWR (power supply +) “p & T sensor”
4-pole connector,
coded
nominal
output voltage
3.3 V
Uo = 8.2 V
Io = 396 m A
Po = 716 mW
Co = 6.4 μF
Lo = 0.2 mH
Pin 2 DATA + (A)
Pin 3 GND (powersupply –)
Pin 4 DATA (B)
*) values apply for the interconnection of all circuits within each connector
Ultrasonic Transducers
Temperature range
and pressure range
see Marking plate
Class I, Division 1, Groups C and D, Temp. Code T4
Ex ia IIB T4 Ga
ClassI,Zone0AExiaIIBT4Ga
.
-25°C < Tamb < 60°C
,
for extended range see Marking plate
.
In the US install in accordance with the NEC (NFPA70, Article 504)
and ANSI/ISA-RP12.06.01
In Canada install in accordance with CEC part 1
Exia Intrinsically Safe; Securite Intrinseque
Circular connectors M8, female f or interconnection with e xternal p & T s ensors
9215965
M12
ext. Power + DO1
e.g. DO0
M12
Wire size for all terminals: 0,14..0, 5 mm (AWG 24 ... 20)
2
4mm
(AWG 12)
2
EXT. POWER
BAT1
n.c.
DO3
DO0
+-
P1
P2
T1
T2
SENSORS
DISPLAY
LOCK
OFF ON
5..12V
NAMUR
4,5..16V
1.5 mm²
(AWG 16)
:
R:100
S
2..16V
2..16V
DO2
2..16V
DO1
+-
BAT2
+-
+- +- +-
kochami
draft
01
2014-08-27
p&T
p&T
M8 M8
gepr.
kochami
2014-08-27
Control drawing FLOWSIC500 isolated I/O
kochami
Ed.6
02
WARNING: EXPLOSION HAZARD
Substitution of components may impair Intrinsic safety
AVERTISSEMENT: La substituti on
de composants peut compromettre la securite intrinseque.
RISQUE D` EXPLOSION -
2015-09-24
kochami
ZY57
03
2018-05-02