Operation
FLOWSIC500 · Operating Instructions · 8025733/1GMJ/V4-2/2022-07 · © SICK Engineering GmbH 85
Subject to change without notice
p 3.532 bar
T 25.42 °C
p = Pressure currently used for volume conversion
T = Temperature currently used for volume conversion
C 25.7368
K 0.9541
C = Conversion factor
K = Compressibility factor
Z 0.99830
Zb 0.99812
Z = Compression factor at measurement conditions currently
used for volume conversion
Zb = Compression factor at base conditions currently used for
volume conversion
Current events
1 Event
Current events (1 event is reported)
Pressing ENTER opens a list of current reported events.
Use the arrow buttons to toggle through the reported events.
Event Summary
2 Events
Stored status messages: Events since the last time the event
summary was reset (2 events have occurred).
Pressing ENTER opens a list of stored events.
Use the arrow buttons to toggle through the stored events.
Last Event Reset
20.08.2021 10:30:52
Last reset of event summary
Pressing ENTER opens the action “Reset Event Summary”.
“Resetting the event summary” (p. 98).
NOTICE:
A parameter with Malfunction status is shown on the display by a blinking
exclamation mark after the parameter (e. g. Q!).
Main display Description