63
8024638/AE00/V1-0/2019-09| SICK S E R V I C E M A N U A L | MCS200HW
Subject to change without notice
REPAIRS 5
Fig. 78: Display, fastening clips
4 Push the fastening clips to the side.
5 Replace the display.
6 Tighten the fastening clips again.
7 Reconnect the cables.
8 Connect the MCS200HW power supply.
9 Parameterize the IP addresses of the display.
5.1.8 Replacing the 24V power supply unit
1 Disconnect the MCS200HW power supply.
Fig. 79: Device cabinet, 24V power supply unit
1Fastening clip
Tools required
Phillips screwdriver
Spare parts set No. Contents
2099745 Power supply unit 85-264 V, 24 V, 2.5 A
Observe the safety rules for work on electrical systems (see “Special hazards”, page 8).
1 24V power supply unit