7.13 ATS7 Set number of seconds to wait for connection completion
Syntax
Command Description
This parameter setting determines the amount of time to wait for the connection completion when answering or
originating a call.
Parameter Description
no. of seconds to wait for connection completion
000...060
(&F)
Notes
Values bigger than 60 cause no error, but <n> will be set down to maximum value of 60.
•In
<n> of ATS0 of the called party is set to higher values the call establishment may not be successful.
The correlation between
ATS7 and ATS0 is important.
Example: ATS7=30 and ATS0=20 may not allow call establishment.
Read Command
ATS7?
Response(s)
<n>
OK
Write Command
ATS7=<n>
Response(s)
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % ! % ! !
Reference(s)
V.25ter
<n>
(num)(&W)(&V)