EasyManua.ls Logo

Siemens MC55 - AT&D Set Circuit Data Terminal Ready (DTR) Function Mode

Siemens MC55
469 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55 AT Command Set
4.3 AT&D
s
m
obil
e
MC55_ATC_V01.05 Page 91 of 469 2/10/04
Confidential / Released
4.3 AT&D Set circuit Data Terminal Ready (DTR) function mode
Syntax
Command Description
This parameter determines how the TA responds when circuit 108/2 (DTR) is changed from ON to OFF during
data mode.
Parameter Description
[0] TA ignores status of DTR.
1 ON->OFF on DTR: Change to command mode while retaining the connected
call.
2
(&F)
ON->OFF on DTR: Disconnect data call, change to command mode. During
state DTR = OFF is auto-answer off.
Exec Command
AT&D[<value>]
Response(s)
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % § % % %
Reference(s)
V.25ter
<value>
(num)(&W)(&V)

Table of Contents