17.3 AT^SBC
s
m
obil
e
MC55_ATC_V01.05 Page 430 of 469 2/10/04
Confidential / Released
17.3 AT^SBC Battery charging / discharging and charge control
Responses returned by the AT^SBC command vary with the operating mode of the ME:
Normal mode: ME is switched on by Ignition pin and running the SLEEP, IDLE, TALK or DATA mode. Charger
is not connected.
AT^SBC can be used to query the battery capacity and the power consumption of ME and
application (if value of application was specified before as
<current>).
Normal mode + charging: Allows charging while ME is switched on by Ignition pin and running the SLEEP,
IDLE, TALK or DATA mode.
AT^SBC returns only charger status and power consumption of ME / application.
Percentage of battery capacity is not available.
Charge-only mode: Allows charging while ME is detached from GSM network. When started, the mode is indi-
cated by the URC "^SYSSTART CHARGE-ONLY MODE".
AT^SBC returns only charger status and power
consumption of ME / application. Percentage of battery capacity is not available. In Charge-only mode a lim-
ited number of AT commands is accessible (see 17.3.1). There are several ways to activate the Charge-only
mode:
- from Power Down mode: Connect charger while ME was powered down with
AT^SMSO
- from Normal mode: Connect charger, then enter AT^SMSO.
Alarm mode: The battery can be charged while the ME stays in Alarm mode, but
AT^SBC returns only charger
status and power consumption of ME / application. Percentage of battery capacity is not available.
For details about charging please refer to [2].
Syntax
Test Command
AT^SBC=?
Response(s)
^SBC:(list of supported <bcs>s), (list of supported <bcl>s), (list of supported <mpc>s)
OK
Read Command
AT^SBC?
Response(s)
^SBC: <bcs>, <bcl>, <mpc>
OK
ERROR
+CME ERROR: <err>
Write Command
AT^SBC=<current>
Response(s)
OK
ERROR
+CME ERROR: <err>