EasyManua.ls Logo

Siemens MC55 - AT^SSMSS Set Short Message Storage Sequence

Siemens MC55
469 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55 AT Command Set
12.24 AT^SSMSS
s
m
obil
e
MC55_ATC_V01.05 Page 355 of 469 2/10/04
Confidential / Released
12.24 AT^SSMSS Set Short Message Storage Sequence
Syntax
Command Description
The short message storage ''MT'' (see AT+CPMS) is a logical storage. It consists of two physical storages ''ME''
and ''SM''. This command allows to select the sequence of addressing this storage.
Parameter Description
MT sequence
0
(&F)
''MT'' storage is ''ME'' then ''SM
1 ''MT'' storage is ''SM'' then ''ME''
Note
Access to the SIM storage is faster. For compatibility with previous software re-leases, the ''MT'' sequence
<seq>=0 is the factory default.
Test Command
AT^SSMSS=?
Response(s)
^SSMSS: (list of supported) <seq>s
Read Command
AT^SSMSS?
Response(s)
^SSMSS: <seq>
OK
Write Command
AT^SSMSS=<seq>
Response(s)
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % % % % %
Reference(s)
SIEMENS
<seq>
(num)

Table of Contents