EasyManua.ls Logo

Siemens MC55 - AT+FCLASS Fax: Select, Read or Test Service Class

Siemens MC55
469 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55 AT Command Set
11.6 AT+FCLASS
s
m
obil
e
MC55_ATC_V01.05 Page 288 of 469 2/10/04
Confidential / Released
11.6 AT+FCLASS Fax: Select, read or test service class
Syntax
Command Description
The ME is set to a particular mode of operation (data, fax). This causes the MA to process information in a man-
ner suitable for that type of information.
Parameter Description
[0]
(&F)
data (e.g. EIA/TIA-602 or ITU V.25ter)
1 Fax class 1 (EIA/TIA-578-A, Service Class 1)
2 Fax class 2 (EIA/TIA SP-2388, an early draft version of EIA/TIA-592-A - Ser-
vice class 2.1)
Notes
Using Error Correcting Mode (ECM) when sending FAXes over GSM should be avoided
Test Command
AT+FCLASS=?
Response(s)
(list of supported <n>s)
OK
Read Command
AT+FCLASS?
Response(s)
<n>
OK
Write Command
AT+FCLASS=<n>
Response(s)
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % ! % ! !
Reference(s)
EIA/TIA-592-A
<n>
(num)(&W)(&V)

Table of Contents