16.9 AT^SNFA Set or query of microphone attenuation
Syntax
Command Description
The test command returns the supported values of the parameter <atten>.
The read command returns the current attenuation value on the microphone path for the current audio device
(selected by
AT^SNFS).
Write command controls the large-scale attenuation on the microphone path for the current audio device
(selected by
AT^SNFS) with the following restrictions:
It is not allowed for audio device 1
As long as the microphone is muted, the write command is temporarily disabled
Setting of value 0 is not allowed (use
AT^SNFM=0 for this).
For values greater than 32767, 32767 will be used.
Test Command
AT^SNFA=?
Response(s)
^SNFA: (list of supported <atten>s)
OK
Read Command
AT^SNFA?
Response(s)
^SNFA: <atten>
OK
Write Command
AT^SNFA=<atten>
Response(s)
OK