MC55 AT Command Set
12.18 AT^SLMS
s
m
obil
e
MC55_ATC_V01.05 Page 345 of 469 2/10/04
Confidential / Released
12.18 AT^SLMS List SMS Memory Storage
Syntax
Command Description
The execute command indicates the maximum capacity of each SMS storage type and the number of locations
currently used.
Parameter Description
Maximum number of messages storable in the SMS memory of the SIM (physical storage "SM")
Maximum number of messages storable in the SMS memory of the Mobile Equipment (physical storage "ME")
Sum of "SM" and "ME", indicated as "MT". Maximum number of all messages storable in the SIM memory and
the Mobile Equipment memory.
Number of messages currently stored in the SMS memory of the SIM (physical storage "SM")
Test Command
AT^SLMS=?
Response(s)
OK
Exec Command
AT^SLMS
Response(s)
^SLMS: ''MT'',<total3>, <used3>
^SLMS: ''SM'',<total1>, <used1>
^SLMS: ''ME'',<total2>, <used2>
OK
ERROR
+CMS ERROR
PIN ASC0 ASC1 MUX1 MUX2 MUX3
% % % % % %
Reference(s)
SIEMENS
<total1>
(num)
<total2>
(num)
<total3>
(num)