MC55 AT Command Set
7.23 AT^SLCC
s
m
obil
e
MC55_ATC_V01.05 Page 172 of 469 2/10/04
Confidential / Released
Use the write command to activate or deactivate event reporting for URC "^SLCC". Event reporting can be
enabled separately for each interface. Interface settings are saved with
AT&W and can be displayed with AT&V.
Parameter Description
call identification number as described in GSM02.30 subclause 4.5.5.1; this number can be used in AT+CHLD
command operations
[0]
(&F)
presentation of URC "^SLCC" disabled
1 presentation of URC "
^SLCC" enabled
0 mobile originated call (MOC)
1 mobile terminated call (MTC)
state of the call
0active
1 held
2dialing (MOC)
3 alerting (MOC)
4 incoming (MTC)
5 waiting (MTC)
6 terminating: The call is not active anymore, but inband information is still avail-
able.
7 dropped: The call has been suspended by the network, but may be resumed
later.
bearer/teleservice
0voice
1 data
2fax
3 voice followed by data, voice mode (only in connection with single numbering
scheme
AT+CSNS)
4 alternating voice/data, voice mode (only in connection with single numbering
scheme
AT+CSNS)
5 alternating voice/fax, voice mode (only in connection with single numbering
scheme
AT+CSNS)
6 voice followed by data, data mode (only in connection with single numbering
scheme
AT+CSNS)
<idx>
(num)
<n>
(num)(&W)(&V)
<dir>
(num)
<stat>
(num)
<mode>
(num)