EasyManua.ls Logo

Siemens MC55 - Page 257

Siemens MC55
469 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55 AT Command Set
10.8 AT+CGQMIN
s
m
obil
e
MC55_ATC_V01.05 Page 257 of 469 2/10/04
Confidential / Released
<cid>.
A special form of the set command,
AT+CGQMIN= <cid> causes the minimum acceptable profile for context
number
<cid> to become undefined. In this case no check is made against the negotiated profile.
AT&F and ATZ will undefine the minimum QoS profiles of every context which is not active or not online.
Parameter Description
Parameter specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is
used in other PDP context-related commands.
1...2
Precedence class
[0] network subscribed value
1 High Priority
Service commitments shall be maintained ahead of precedence classes 2 and
3
2Normal priority
Service commitments shall be maintained ahead of precedence class 3
3 Low priority
Service commitments shall be maintained
Delay class
The delay parameter defines the end-to-end transfer delay incurred in the transmission of SDUs through the
GPRS network(s).
[0] network subscribed value
1..4 SDU size: 128 octets:
SDU size: 1024 octets:
<cid>
(num)
<precedence>
(num)
<delay>
(num)
Delay Class Mean Transfer Delay 95 percentile
1 (Predictive) <0.5 <1.5
2 (Predictive) <5 <25
3 (Predictive) <50 <250
4 (Best Effort) Unspecified
Delay Class Mean Transfer Delay 95 percentile
1 (Predictive) <0.5 <1.5
2 (Predictive) <5 <25
3 (Predictive) <50 <250
4 (Best Effort) Unspecified

Table of Contents

Related product manuals