EasyManua.ls Logo

Siemens MC55 - Page 415

Siemens MC55
469 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55 AT Command Set
16.15 AT^SNFS
s
m
obil
e
MC55_ATC_V01.05 Page 415 of 469 2/10/04
Confidential / Released
Examples
EXAMPLE 1
Suppose a user wishes to use alternatively a handsfree device and a handset. The handset can be connected
to the first analog interface and adjusted to audio mode 4. The handsfree device can be attached to the sec-
ond analog interface and adjusted to audio mode 2. The factory defaults of
AT^SAIC need not be changed.
Settings for the handset:
Settings for the handsfree device:
To store the configuration to the user defined audio profile:
To switch back and forth:
EXAMPLE 2
The following example illustrates a combination of a handset and a handsfree device connected to other inter-
faces than those assumed as factory default.
Settings for a handset connected to the second analog interface and adjusted to audio mode 4:
AT^SNFS=4
OK
AT^SAIC?
Factory default of AT^SAIC assigned to audio mode 4.
^SAIC: 2,1,1
OK
AT^SNFS=2
OK
AT^SAIC?
Factory default of AT^SAIC assigned to audio mode 2.
^SAIC: 2,2,2
OK
AT^SNFW
Stores the audio mode and the interface.
OK
AT^SNFS=4
Switches to the handset connected to analog interface 1.
OK
AT^SNFS=2
Switches to the handsfree device at analog interface 2.
OK
AT^SNFS=4
OK
AT^SAIC=2,2,2
OK

Table of Contents

Related product manuals