MC55 AT Command Set
16.17 AT^SNFV
s
m
obil
e
MC55_ATC_V01.05 Page 420 of 469 2/10/04
Confidential / Released
Notes
The read and write commands refer to the active audio mode.
The write command works only in audio modes 2 to 6!
Any change to
<outStep> takes effect in audio modes 2 to 6. That is, when you change <outStep> and
then select another mode with
AT^SNFS, the same step will be applied. Nevertheless, the actual volume can
be quite different, depending on the values of
<outCalibrate> set in each mode. The only exception is
audio mode 1 which is fixed to
<outStep>=4.
<outStep> is stored non-volatile when the ME is powered down with AT^SMSO or reset with AT+CFUN=1,1.
<outStep> is not stored by AT^SNFW.
<outStep> can also be changed by AT^SNFO (Chapter 16.13, page 410) and AT+CLVL (Chapter 16.4, page
395).