MC55 AT Command Set
2.13 AT^SCFG
s
m
obil
e
MC55_ATC_V01.05 Page 56 of 469 2/10/04
Confidential / Released
Command Description
The read command returns a list of all supported parameters with their current values.
The write command allows to query a configuration parameter (no value was given) or to set its value(s).
The following error codes are used:
"+CME ERROR: operation temporary not allowed" ... change of parameter value(s) temporarily not allowed
"+CME ERROR: invalid index" ... invalid parameter name or invalid value(s).
"+CME ERROR: invalid characters in text string" ... a character set conversion of parameter value(s) failed
"+CME ERROR: unknown" ... other errors
Write Command
Configuration of URC "^SLCC" Call Status Indication
AT^SCFG="URC/CallStatus/SLCC"[, <sucs>]
Response(s)
^SCFG: "URC/CallStatus/SLCC", <sucs>
Write Command
URC indication in datamode via RING line:
AT^SCFG="URC/Datamode/Ringline"[, <udri>]
Response(s)
^SCFG: "URC/Datamode/Ringline", <udri>
Write Command
URC indication via RING line:
AT^SCFG="URC/Ringline"[, <uri>]
Response(s)
^SCFG: "URC/Ringline", <uri>
Write Command
Duration of active RING line for URC indications:
AT^SCFG="URC/Ringline/ActiveTime"[, <urat>]
Response(s)
^SCFG: "URC/Ringline/ActiveTime", <urat>
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % % % % %
Reference(s)
SIEMENS