Parameterizing the Mobile Panel
5.10 Server time
TP1000F Mobile RO
Operating Instructions, 08/2017, A5E39831415-AA
109
5.10
Server time
To obtain the time of the HMI device from a time server, you can specify up to four different
time servers. The time is synchronized using the "Network Time Protocol". The
synchronization cycle applies to all configured time servers.
Requirement
The HMI device and time server are located in the same network.
The Control Panel is open.
Procedure
1. Open the "PROFINET" dialog using the "PROFINET" icon.
2. Change to the "NTP" tab.
Text box for time servers 1 to 4
Button for configuring the time servers
3. If you want to use the time of a time server, activate "Automatically synchronize with …".
4. Under "Update rate", enter the time interval in seconds after which the HMI device is to
synchronize the time.
Permitted value range: 1 ... 60 000 000 seconds.
5. Press the "Configure" button.
The following dialog is displayed:
If you do not enter a time, the message "Second field wrong data type." will appear. Enter
a time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC HMI TP1000F Mobile RO and is the answer not in the manual?

Siemens SIMATIC HMI TP1000F Mobile RO Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC HMI TP1000F Mobile RO
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals