Technical specifications
9.7 Technical specifications
TP1000F Mobile RO
Operating Instructions, 08/2017, A5E39831415-AA
167
Protection against foreign objects and water
The device meets the requirements of IEC 60529.
IP65 all-round Applies to HMI device including connecting cable under the
following conditions:
• The terminal compartment cover is closed.
• The USB port is closed using a cover cap.
Type 4X/Type 12 (indoor use only)
Applies if indicated on the nameplate
Degree of pollution and overvoltage category
The device meets the following requirements according to IEC 61131-2:2007.
Weight
You can find the information based on length on the Internet at:
SIMATIC HMI accessories
(https://mall.industry.siemens.com/mall/en/de/Catalog/Products/10030052) *
Bending radius,
≥ 4-times the outside diameter of the line
Rated condition,
0 to 55 °C
* To navigate directly to the information abou
t the connecting cable, enter the article number of the
connecting cable in the "Site Explorer" text box.
Connection boxes
Mechanics
Weight without
packaging
Connection box standard, connection box advanced Approx. 750 g