As in the example above, you obtain the interconnection if you congured the interfaces of the
converter with p0015 = 7 in the basic commissioning.
Quick commissioning (Page 106)
An overview of all the parameters that belong to the command data sets is provided in the List
Manual.
Note
The converter requires approx. 4 ms to switch over the command data set.
Parameter
Parameter Description Factory settings
p0010 Drive commissioning parameter lter 1
r0050 CO/BO: Command data set CDS eective -
p0170 Number of command data sets (CDS) 2
r0722 CO/BO: CU digital inputs, status -
p0809[0 … 2] Copy command data set CDS 0
p0810 BI: Command data set selection CDS bit 0 0
p0811 BI: Command data set selection CDS bit 1 0
p0840[C] BI: ON/OFF (OFF1) Dependent on the
converter
Advanced commissioning
8.11 Switching over the drive control (command data set)
Distributed converter for SIMOGEAR geared motors
228 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL