p1020 p1021 p1022 p1023 Resulting setpoint
1 0 0 1 p1001 + p1004
0 1 0 1 p1002 + p1004
1 1 0 1 p1001 + p1002 + p1004
0 0 1 1 p1003 + p1004
1 0 1 1 p1001 + p1003 + p1004
0 1 1 1 p1002 + p1003 + p1004
1 1 1 1 p1001 + p1002 + p1003 + p1004
Selecting the xed speed setpoint, binary
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQWVHOHFWLRQELW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQWHIIHFWLYH
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
)L[HGVSHHGVHWSRLQW
U
S
S
S
S
S
S
S
S
S
Figure 8-45 Binary selection of the xed speed setpoint
Table 8-51 Resulting setpoint
p1020 p1021 p1022 p1023 Resulting setpoint
0 0 0 0 0
1 0 0 0 p1001
0 1 0 0 p1002
1 1 0 0 p1003
0 0 1 0 p1004
1 0 1 0 p1005
0 1 1 0 p1006
1 1 1 0 p1007
0 0 0 1 p1008
1 0 0 1 p1009
0 1 0 1 p1010
1 1 0 1 p1011
0 0 1 1 p1012
1 0 1 1 p1013
0 1 1 1 p1014
1 1 1 1 p1015
Advanced commissioning
8.16 Setpoints
Distributed converter for SIMOGEAR geared motors
266 Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL