Example
After it has been switched on, a conveyor belt only runs with two dierent velocities. The motor
should now operate with the following corresponding speeds:
• The signal at digital input 0 switches the motor on and accelerates it up to 300 rpm.
• The signal at digital input 1 accelerates the motor up to 2000 rpm.
• With signals at both digital inputs, the motor accelerates up to 2300 rpm.
Table 8-52 Settings for the application example
Parameter Description
p1001[0] =
300.000
Fixed speed setpoint 1
p1002[0] =
2000.000
Fixed speed setpoint 2
p0840[0] = 722.0 ON/OFF1: Switches on the motor with digital input 0
p1070[0] = 1024 Main setpoint: Interconnects the main setpoint with a xed speed setpoint.
p1020[0] = 722.0 Fixed speed setpoint selection bit 0: Interconnects xed speed setpoint 1 with dig‐
ital input 0 (DI 0).
p1021[0] = 722.1 Fixed speed setpoint selection bit 1: Interconnects xed speed setpoint 2 with dig‐
ital input 1 (DI 1).
p1016 = 1 Fixed speed setpoint mode: Directly selects xed speed setpoints.
Table 8-53 Resulting xed speed setpoints for the application example
Fixed speed setpoint selected via Resulting setpoint
DI 0 = 0 Motor stops
DI 0 = 1 and DI 1 = 0 300 rpm
DI 0 = 1 and DI 1 = 1 2300 rpm
Parameter
Parameter Description Factory setting
p1001[D] CO: Fixed speed setpoint 1 0 rpm
p1002[D] CO: Fixed speed setpoint 2 0 rpm
p1003[D] CO: Fixed speed setpoint 3 0 rpm
p1004[D] CO: Fixed speed setpoint 4 0 rpm
p1005[D] CO: Fixed speed setpoint 5 0 rpm
p1006[D] CO: Fixed speed setpoint 6 0 rpm
p1007[D] CO: Fixed speed setpoint 7 0 rpm
p1008[D] CO: Fixed speed setpoint 8 0 rpm
p1009[D] CO: Fixed speed setpoint 9 0 rpm
p1010[D] CO: Fixed speed setpoint 10 0 rpm
p1011[D] CO: Fixed speed setpoint 11 0 rpm
p1012[D] CO: Fixed speed setpoint 12 0 rpm
Advanced commissioning
8.16 Setpoints
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL 267