EasyManua.ls Logo

Simphoenix V800 Series - 7.37 PARAMETER SELECTION OF COMPENSATION PID CONTROLLER (GROUP F9.1)

Default Icon
246 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description Of Specific Functions
V800 Series High Performance Closed-Loop Vector Inverter User Manual
180
7.37 PARAMETER SELECTION OF COMPENSATION PID
CONTROLLER (GROUP F9.1)
There are 4 groups of compensation PID controller parameters, and their switching means are shown in
Figure 7-67 ([9.1.21=0023]):
Time
Time
Frequency
Selection of controller
parameters
PID group 2 effective
Lower limit for group 1, 2
parameter switching
PID group 1 effective
Upper limit for group
1, 2 parameter switching
PID group 4 effective
PID group 3 effective
Upper limit for group
2, 3 parameter switching
Upper limit for group
3, 4 parameter switching
Lower limit for group
2, 3 parameter switching
Lower limit for group
3, 4 parameter switching
[F9.1.23]
[F9.1.25]
[F9.1.27]
[F9.1.28]
[F9.1.26]
[F9.1.24]
[F9.0.03]~[F9.0.07]
[F9.1.29]~[F9.1.33]
[F9.1.34]~[F9.1.38]
[F9.1.39]~[F9.1.43]
Figure 7-67 Sketch of compensation PID parameter switching