Functional Parameter Table
V800 Series High Performance Closed-Loop Vector Inverter User Manual
6.2.6 ACCELERATION AND DECELERATION CHARACTERISTICS PARAMETERS
Setting Range and Description
Acceleration and
deceleration
characteristics
parameters
_ _ _ X: Accel decele mode
0: Liner acceleration and deceleration
1: S curve acceleration and deceleration
_ _ X _: Unit of acceleration and
deceleration time
0: Sec. (Second)
1: Min. (Minute)
% of S curve at the
bottom
% of S curve at mid
section
Acceleration 4/jog
acceleration time
Deceleration 4/jog
deceleration time
EMS emergency stop
and deceleration time
6.2.7 CARRIER FREQUENCY
Setting Range and Description
Three-phase voltage vector composition
(FF.4.43=##0#) mode: 1.5~12.0KHz
Two-phase voltage vector composition
(FF.4.43 =##1#) mode: 1.5~15.0KHz
_ _ _ X: Load linkage adjustment
0: Void 1: Effective
_ _ X _: Temperature linkage adjustment
0: Void 1: Effective
_ X _ _: Reference frequency linkage adjustment
0: Void 1: Effective
X _ _ _: Modulation mode
0: Asynchronous modulation
1: Synchronous modulation
2~5: Sound smooth