Functional Parameter Table
V800 Series High Performance Closed-Loop Vector Inverter User Manual
6.2.29 SIMPLE PROGRAMMABLE MULTI-STAGE OPERATION
Setting Range and Description
Selection of
programmable
multi-stage speed
operation mode (H)
_ _ _ X: Function selection
0: Function closed
1: Multi-stage frequency/revolution
operation effective
2: Multi-stage frequency/revolution
operation condition effective (Function
No. 23)
3: Multi-stage PID setting operation
effective
4: Multi-stage PID setting operation
condition effective (Function No. 23)
_ _ X _: Operation mode
0: Single cycle
1: Single cycle stop mode
2: Continuous cycle
3: Continuous cycle stop mode
4: Keeping the final value
5: Keeping the final value stop mode
_ X _ _: Selection of breakpoint/stop
recovery mode
0: Restore running at the first stage
1: Start running at the interruption time
(effective for multi-stage frequency/
revolution operation)
2: Start running at the stage of interruption
X _ _ _: Power-off status storage
0: Not stored 1: Stored
_ _ _ X: Hz of each stage
0: Multi-stage frequency setting 1~15/
Process PID multi-stage setting 1~7
1: Frequency command (F0.1.16)/
Process PID setting (F7.0.01)
_ _ X _: Direction setting
0: FWD
1: REV
2: Determined by the running command
channel
_ X _ _: Accele/decele of each stage
0: Acceleration and deceleration time 1
1: Acceleration and deceleration time 2
2: Acceleration and deceleration time 3
3: Acceleration and deceleration time 4
X _ _ _: Each stage time unit
0: Sec. 1: Min.