216
HEAD WARNINGS
Not initialized
• Indicates that head data is not ready. This is only displayed when the printer is initializing a newly
installed head, or if the initialization process failed.
• Correct condition - wait at least 60 seconds after the error is first displayed. If the error persists, open
the top cover and unclip the head cable connected to the corresponding head. Wait a few seconds
and then reconnect the head cable to the head and close the top cover (see “Head Replacement” on
page 117 for details). If the error persists there is likely a problem with either the head or the head
cable; please contact Stratasys Customer Support or your regional Stratasys office for further
assistance (see “Getting Help” on page 204 for contact information).
Order new model head
• Indicates that the model head has reached 1350 build hours, and is near its odometer limit. This
warning is displayed as a reminder to order a replacement head for the one that is approaching its
odometer limit. Build hours are available within the head’s Head Details page (see “Viewing Head
Details” on page 63).
• Correct condition - you are still able to build using this head, but part quality may be affected. Once
the head’s odometer limit is reached, you will be prompted to change the head (see “Head
Replacement” on page 117).
Order new support head
• Indicates that the support head has reached 1350 build hours, and is near its odometer limit. This
warning is displayed as a reminder to order a replacement head for the one that is approaching its
odometer limit. Build hours are available within the head’s Head Details page (see “Viewing Head
Details” on page 63).
• Correct condition - you are still able to build using this head, but part quality may be affected. Once
the head’s odometer limit is reached, you will be prompted to change the head (see “Head
Replacement” on page 117).
HEAD ERRORS
Replace model head
• Indicates that the model head has reached its 1500 build hour odometer limit. This error message is
displayed as a reminder that you should replace the head before starting another build. Build hours
are available within the head’s Head Details page (see “Viewing Head Details” on page 63).
• Correct condition - you are able to continue building using this head but it is recommended that you
change the head prior to starting a new build (see “Head Replacement” on page 117).
Replace support head
• Indicates that the support head has reached its 1500 build hour odometer limit. This error message
is displayed as a reminder that you should replace the head before starting another build. Build
hours are available within the head’s Head Details page (see “Viewing Head Details” on page 63).
• Correct condition - you are able to continue building using this head but it is recommended that you
change the head prior to starting a new build (see “Head Replacement” on page 117).
Note: The warnings and errors listed below are displayed within the notifications
area of the Head Details page. See “Viewing Head Details” on page 63 for
details.