4-30 Sun Netra T5220 Server Service Manual • January 2012
4. Gain access to the ALOM CMT sc> prompt.
5. Run the showfaults command.
■ If the fault was detected by the host and the fault information persists, the
output will be similar to the following example:
■ If the showfaults command does not report a fault with a UUID, then you do
not need to proceed with the following steps because the fault is cleared.
6. Run the clearfault command.
7. Switch to the system console.
8. Issue the fmadm repair command with the UUID.
Use the same UUID that you used with the clearfault command.
4.7 Replacing the Battery
4.7.1 Removing the Battery
1. Prepare the server for battery removal. See Section 4.1, “Powering Off and
Powering On the Server” on page 4-1.
sc> showfaults
Last POST Run: Wed Jun 29 11:29:02 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/MB/CMP0/BR2/CH1/D0 Host detected fault, MSGID:
SUN4V-8000-DX UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc> clearfault 7ee0e46b-ea64-6565-e684-e996963f7b86
sc> console
# fmadm repair 7ee0e46b-ea64-6565-e684-e996963f7b86