1-30 Sun Netra T5220 Server Service Manual • January 2012
TABLE 1-8 shows typical combinations of ALOM CMT CLI variables and associated
POST modes.
1.5.2 Changing POST Parameters
1. Access the ALOM CMT CLI sc> prompt:
At the console, issue the #. key sequence:
2. Use the ALOM CMT CLI sc> prompt to change the POST parameters.
Refer to
TABLE 1-7 for a list of ALOM CMT CLI POST parameters and their values.
The setkeyswitch parameter sets the virtual keyswitch, so this parameter does
not use the setsc command. For example, to change the POST parameters using
the setkeyswitch command, enter the following:
TABLE 1-8 ALOM CMT CLI Parameters and POST Modes
Parameter
Normal Diagnostic Mode
(Default Settings) No POST Execution
Diagnostic Service
Mode
Keyswitch Diagnostic
Preset Values
diag_mode normal off service normal
setkeyswitch
*
* The setkeyswitch parameter, when set to diag, overrides all the other ALOM CMT CLI POST variables.
normal normal normal diag
diag_level max n/a max max
diag_trigger power-on-reset
error-reset
none all-resets all-resets
diag_verbosity normal n/a max max
Description of POST
execution
This is the default POST
configuration. This
configuration tests the
system thoroughly, and
suppresses some of the
detailed POST output.
POST does not
run, resulting in
quick system
initialization. This
is not a suggested
configuration.
POST runs the full
spectrum of tests
with the maximum
output displayed.
POST runs the full
spectrum of tests
with the maximum
output displayed.
#.
sc> setkeyswitch diag