4-28 Sun Netra T5220 Server Service Manual January 2012
4.6.4 Verifying Successful Replacement of a Faulty
FB-DIMM
1. Access the ALOM CMT sc> prompt.
Refer to the Sun Integrated Lights Out Management 2.0 Supplement for the Sun Netra
T5220 Server for instructions.
2. Run the showfaults -v command to determine how to clear the fault.
The method you use to clear a fault depends on how the fault is identified by the
showfaults command.
Examples:
If the fault is a host-detected fault (displays a UUID), continue to Step 3. For
example:
If the fault was detected by POST and resulted in the FB-DIMM being disabled,
such as the following,
In most cases, the replacement of the faulty FB-DIMM(s) is detected when the
service processor is power cycled. In this case, the fault is automatically cleared
from the system. If the fauilt is still displayed by the showfaults command,
then run the enablecomponent command to enable the FB-DIMM and clear
the fault.
3. Perform the following steps to verify the repair:
sc> showfaults
Last POST Run: Wed Jun 29 11:29:02 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/MB/CMP0/BR2/CH1/D0 Host detected fault, MSGID:
SUN4V-8000-DX UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc> showfaults
Last POST Run: Wed Jun 27 21:29:02 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/MB/CMP0/BR3/CH1/D1 SP detected fault:
/SYS/MB/CMP0/BR3/CH1/D1 Forced fail (POST)
sc> enablecomponent /SYS/MB/CMP0/BR3/CH1/D1