EasyManua.ls Logo

Sun Microsystems Netra T5220 - Page 155

Sun Microsystems Netra T5220
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Replacing Chassis Components 5-25
Section 6.1.4, “Reinstalling the Server Chassis in the Rack” on page 6-5
Section 6.1.5, “Reconnecting Cables to the Server” on page 6-7
Section 6.1.6, “Powering On the Server” on page 6-8
Note After replacing the power distribution board and powering on the system,
you must run the ALOM CMT setcsn and setcpn commands to set the
electronically readable chassis serial number and server part number.
6. At the ALOM CMT command line interface, use the setcsn command to set the
chassis serial number and the setcpn command to set the server part number
on the power distribution board.
The following is an example of the command-line dialog used to set the chassis
serial number and server part number for the server.
Caution When performing the following steps, use special care to enter the correct
numbers. Once the power distribution board has been programmed with a chassis
serial number or server part number, the number cannot be changed.
sc> setsc sc_servicemode true
Warning: misuse of this mode may invalidate your warranty.
sc> setcsn -c
chassis_serial_number
Are you sure you want to permanently set the Chassis Serial Number
to
chassis_serial_number [y/n]? y
setcsn: Chassis serial number recorded.
sc> setcpn -p
chassis_part_number
Are you sure you want to permanently set the Chassis Part Number
to
chassis_part_number [y/n]? y
setcpn: Chassis part number recorded.
sc> showplatform
Sun-Netra-T5220
Chassis Serial Number:
chassis_serial_number
Domain Status
------ ------
SO Running
sc> setsc sc_servicemode false

Table of Contents

Related product manuals