1-22 Sun Netra T5220 Server Service Manual • January 2012
■ Example of the showfaults command when no faults are present:
■ Example of the showfaults command displaying an environmental fault:
■ Example showing a fault that was detected by POST. These kinds of faults are
identified by the message Forced fail reason where reason is the name of the
power-on routine that detected the failure.
■ Example showing a fault that was detected by the PSH technology. These kinds
of faults are identified by the text
Host detected fault and by a UUID.
sc> showfaults
Last POST run: THU MAR 09 16:52:44 2006
POST status: Passed all devices
No failures found in System
sc> showfaults
Last POST Run: Wed Jul 18 11:44:47 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/FANBD0/FM0 SP detected fault: TACH at /SYS/FANBD0/FM0/F1
has exceeded low non-recoverable threshold.
sc> showfaults
Last POST Run: Wed Jun 27 21:29:02 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/MB/CMP0/BR3/CH1/D1 SP detected fault:
/SYS/MB/CMP0/BR3/CH1/D1 Forced fail (POST)
sc> showfaults -v
Last POST Run: Wed Jun 29 11:29:02 2007
Post Status: Passed all devices
ID Time FRU Fault
0 Jun 30 22:13:02 /SYS/MB Host detected fault, MSGID:
SUN4V-8000-N3 UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86