1-24 Sun Netra T5220 Server Service Manual • January 2012
EXAMPLE 1-1 shows abridged output of the showenvironment command.
EXAMPLE 1-1 showenvironment Command Output
sc> showenvironment
------------------------------------------------------------------------------
System Temperatures (Temperatures in Celsius):
------------------------------------------------------------------------------
Sensor Status Temp LowHard LowSoft LowWarn HighWarn
HighSoft HighHard
------------------------------------------------------------------------------
/SYS/MB/T_AMB OK 29 -10 -5 0 50 55 60
/SYS/MB/CMP0/T_TCORE OK 50 -14 -9 -4 86 96 106
/SYS/MB/CMP0/T_BCORE OK 51 -14 -9 -4 86 96 106
/SYS/MB/CMP0/BR0/CH0/D0/T_AMB OK 41 -10 -8 -5 95 100 105
...
------------------------------------------------------------------------------
System Indicator Status:
------------------------------------------------------------------------------
/SYS/LOCATE /SYS/SERVICE /SYS/ACT
OFF OFF ON
------------------------------------------------------------------------------
/SYS/PSU_FAULT /SYS/TEMP_FAULT /SYS/FAN_FAULT
OFF OFF OFF
------------------------------------------------------------------------------
System Disks:
------------------------------------------------------------------------------
Disk Status Service OK2RM
------------------------------------------------------------------------------
/SYS/HDD0 OK OFF OFF
/SYS/HDD1 NOT PRESENT OFF OFF
...