1-36 Sun Netra T5220 Server Service Manual January 2012
1. After replacing a faulty FRU, at the ALOM CMT CLI prompt use the
showfaults command to identify POST detected faults.
POST detected faults are distinguished from other kinds of faults by the text:
Forced fail, and no UUID number is reported.
Example:
If no fault is reported, you do not need to do anything else. Do not perform the
subsequent steps.
2. Use the enablecomponent command to clear the fault and remove the
component from the ASR blacklist.
Use the FRU name that was reported in the fault in Step 1.
The fault is cleared and should not show up when you run the showfaults
command. Additionally, the Service Required LED is no longer on.
3. Power cycle the server.
You must reboot the server for the enablecomponent command to take effect.
4. At the ALOM CMT CLI prompt, use the showfaults command to verify that
no faults are reported.
EXAMPLE 1-6 POST Detected Fault
sc> showfaults
Last POST Run: Wed Jun 27 21:29:02 2007
Post Status: Passed all devices
ID FRU Fault
0 /SYS/MB/CMP0/BR2/CH0/D0 SP detected fault: /SYS/MB/CMP0/BR2/CH0/D0 Forced
fail (POST)
EXAMPLE 1-7 Using the enablecomponent Command
sc> enablecomponent /SYS/MB/CMP0/BR2/CH0/D0
TABLE 1-9 Verifying Cleared Faults Using the showfaults Command
sc> showfaults
Last POST run: THU MAR 09 16:52:44 2006
POST status: Passed all devices
No failures found in System